מומחי הפרובים מחכים

972-03-923-2277+

אין כלום בעגלה שלך.

מצאו את הפרוב המתאים לכם

פרובים מכל הסוגים
מתאימים לכל החברות

עכשיו

במחירי השקה

High Voltage Differential Probes BumbleBee® Series
הצג
Placeholder for ajax description replacement

Current Probe CP4020

  • 100 kHz bandwidth for accurate AC/DC current measurements
  • Supports 20 Arms continuous and up to 60 A peak current
  • Dual sensitivity: 50 mV/A and 2 mV/A for flexible diagnostics
  • ±2% typical accuracy for precise results in test environments
  • Compact, battery-powered design ideal for field and lab use

Current Probe CP4050

  • Bandwidth: DC to 1 MHz
  • Peak current measurement up to 140 A
  • Dual sensitivity: 500 mV/A and 50 mV/A
  • DC measurement accuracy: ±3% ±20 mA (500 mV/A); ±4% ±200 mA (50 mV/A)
  • Maximum conductor diameter: 10.3 mm

Current Probe CP4070

  • Measures up to 200A AC/DC.
  • Bandwidth of 150 kHz.
  • Easy BNC connection to oscilloscopes.
  • Suitable for use with a wide range of instruments, including Siglent oscilloscopes.
  • Ideal for power electronics, automotive, and industrial applications.

Current Probe CP4070A

  • DC to 300 kHz bandwidth
  • 70 A RMS / 200 A peak current range
  • Dual range: 100 mV/A and 10 mV/A
  • Accuracy: ±2% typical
  • Fast rise time: ≤1.2 µs

Current Probe CP6030

  • Bandwidth: DC to 50 MHz
  • Dual measurement ranges: 5 A (1 V/A) and 30 A (0.1 V/A)
  • High accuracy: ±1% ±1 mA (5 A range); ±1% ±10 mA (30 A range)
  • Over-current protection with audible and visual indicators
  • Automatic zero adjustment for measurement precision

Current Probe CP6030A

  • 100 MHz bandwidth for accurate high-frequency current measurements.
  • Dual measurement ranges: 5 A (1 V/A) and 30 A (0.1 V/A).
  • High accuracy: ±1% ±1 mA (5 A); ±1% ±10 mA (30 A).
  • Over-current protection with audible and visual indicators.
  • Automatic zero adjustment for stable measurements.

Current Probe CP6150

  • 12 MHz bandwidth for accurate high-frequency current measurements.
  • Dual measurement ranges: 30 A (0.1 V/A) and 150 A (0.01 V/A).
  • High accuracy: ±1% ±10 mA (30 A); ±1% ±100 mA (150 A).
  • Over-current protection with audible and visual indicators.
  • Automatic zero adjustment for stable measurements.

Current Probe CP6500

  • 5 MHz bandwidth with ≤70 ns rise time for accurate waveform capture
  • Dual measurement ranges: 75 A (0.1 V/A) and 500 A (0.01 V/A)
  • High accuracy: ±1% ±10 mA (75 A), ±1% ±100 mA (500 A)
  • Built-in over-current protection with buzzer and LED alerts
  • Compatible with oscilloscopes via standard BNC and powered by 12 V DC adapter

Current Probe CP5030A

  • 100 MHz bandwidth with ≤3.5 ns rise time
  • Dual range: 5 A (1X), 30 A (10X) with 1 V/A and 0.1 V/A transfer ratios
  • High accuracy: ±1% ±1 mA (5 A), ±1% ±10 mA (30 A)
  • Measures peak currents up to 50 A
  • Max conductor diameter of 5 mm, powered by 12 V DC adapter

Current Probe CP5030

  • 50 MHz bandwidth with ≤7 ns rise time
  • Current ranges: 5 A (1X), 30 A (10X)
  • Transfer ratios: 1 V/A (5 A), 0.1 V/A (30 A)
  • Accuracy: ±1% ±1 mA (5 A), ±1% ±10 mA (30 A)
  • Resolution: 1 mA / 10 mA

Current Probe CP5150

  • DC–12 MHz bandwidth and ≤29 ns rise time
  • Dual ranges: 30 A (1X), 150 A (10X)
  • Transfer ratios: 0.1 V/A (30 A), 0.01 V/A (150 A)
  • Measurement resolution: 5 mA (30 A), 50 mA (150 A)
  • Accuracy: ±1% ±10 mA or ±100 mA depending on range

Current Probe CP5500

  • Transfer ratios: 0.1 V/A (75 A), 0.01 V/A (500 A)
  • Accuracy: ±1% ±10 mA (75 A), ±1% ±100 mA (500 A)
  • Resolution: 5 mA (75 A), 50 mA (500 A)
  • Max peak current: 750 A
  • Max conductor diameter: 20 mm
Showing 12 of 16 items
Load More
Placeholder for ajax description replacement