High Voltage Differential Probes BumbleBee® Series
הצג
Placeholder for ajax description replacement

Active Probe ATE2000 with ground blade

  • For Automated Test Equipment (ATE) Designed for in-circuit measurements within automated test environments.
  • High Bandwidth Offers a bandwidth of >2.5 GHz.
  • Voltage Range Has an input dynamic voltage range of ±8V (16Vpp) and an input offset voltage range of ±12V.
  • High Input Impedance Features a high input resistance of 1 MΩ (input to ground) to prevent shorting the test point.
  • Ground Blade Includes a ground blade for repeatable measurements.

Active Probe Sonic® 4000

  • The Sonic 4000 active probe offers best-in-class performance for in-circuit measurements.
  • It has a bandwidth from DC to >4 GHz, high input impedance, low noise, and a ±8V dynamic range.
  • The probe's ±12V input offset capability extends its input voltage range.
  • It features an input capacitance of <0.6 pF and 2MΩ input resistance to minimize circuit loading.
  • The probe tip reference connection has a high impedance to earth ground for safe in-circuit probing.

High Impedance Active Probe Tetris® 1000

  • 1 GHz Bandwidth for accurate high-frequency signal measurements

  • ±8 V Dynamic Range supports a wide range of signal levels

  • High Input Impedance of >1 MΩ with low 0.9 pF capacitance for minimal circuit loading

  • 10:1 Attenuation Ratio ensures safe signal scaling for sensitive instruments

  • Compact and Lightweight with 1.3 m cable and BNC output for universal oscilloscope compatibility

High Voltage Differential Probe BumbleBee®±2000V, 2m

  • High Voltage Differential Probe – Designed for measuring high voltage differentials, up to ±2000V.
  • 2m Cable Length – Comes with a 2-meter cable for flexible measurement setups.
  • Adjustable Attenuation – Offers four selectable input attenuation ranges (500:1, 250:1, 100:1, 50:1) to optimize the signal for the best resolution.
  • Wide Bandwidth – Supports bandwidth up to 400 MHz (depending on attenuation setting).
  • Universal BNC Output – Features a universal BNC output connector for compatibility with various oscilloscopes.

High voltage optically isolated probe FireFly® SMA Input

  • High Bandwidth – Offers a bandwidth greater than 1.5 GHz.
  • Low Input Range – Designed for a low input voltage range of ±1V.
  • High Input Impedance – Has an input impedance of 200 kΩ || 5.1 pF.
  • Fast Rise Time – Features a rise time of less than 250 ps.
  • High CMRR – Exhibits a high Common Mode Rejection Ratio (CMRR).

High Voltage Passive Probe PHV 1000

  • It is a high voltage passive probe. This means it's designed to measure high voltages without needing its own power source, relying on the signal from the circuit it's testing.
  • It has an attenuation ratio of 100:1. This indicates that the probe reduces the input voltage to 1/100th of its actual value, allowing standard oscilloscopes to measure high voltages safely. The attenuation ratio has an accuracy of ±2% at DC.
  • It has a system bandwidth of 120 MHz. This specifies the frequency range over which the probe can accurately measure voltage signals. It also has a rise time of 2.4 ns.
  • The input resistance is 50 MΩ. This high input resistance minimizes the loading effect on the circuit being measured, ensuring accurate readings. The input capacitance is 9.5 pF.
  • It is designed for use with a measuring instrument having an input coupling of 1 MΩ AC/DC. This defines the input impedance that the measuring instrument (typically an oscilloscope) should have for the probe to function correctly.

High Voltage Passive Probes HV-P30A

  • It is a high voltage passive probe designed for high voltage measurements.
  • It has an attenuation ratio of 1000:1.
  • The maximum DC input voltage is 30 kV, and the maximum frequency band voltage is 40 kV.
  • It has a system bandwidth of 50 MHz.
  • It is intended for use in a protected test environment and is not designed for handheld use.

High Voltage Passive Probes PHV 1000-O

  • It is a high-voltage probe designed for use with the OMICRON Lab Bode 100 vector network analyzer.
  • It has a maximum input voltage of 2000V peak.
  • It features a 100:1 attenuation ratio.
  • The system has an input resistance of 50 MΩ and an input capacitance of 7.5 pF.
  • It comes with accessories for easy adaptation to the device under test (DUT).

High Voltage Passive Probes PHVX4kV-2-0

  • It's a passive high voltage probe designed for measurements in power electronics design.
  • It has a maximum input voltage rating of 4000V DC / 4000V peak.
  • It features a bandwidth greater than 600MHz and a 100:1 attenuation ratio.
  • It comes with a 2.0m cable length.
  • It does not include readout function or additional Silicon insulation.

High-Speed Differential Probe HSDP4010

  • High Bandwidth Offers a bandwidth greater than 4 GHz, with 4.2 GHz typical.
  • Differential Voltage Range Designed for a differential voltage range of ±8V (16Vpp).
  • Low Noise Features low input-referred noise, less than 2 mV rms and 100 nV/sqrt(Hz) (preliminary).
  • Fast Rise Time Has a rise time of less than 140 ps (preliminary).
  • High CMRR Exhibits high Common Mode Rejection Ratio (CMRR) with >70 dB at DC, >50 dB at 1 MHz, >45 dB at 10 MHz, >35 dB at 100 MHz, >25 dB at 500 MHz and >25 dB at 1 GHz.

Passive Probe MMCX-P0725

  • Passive Probe – It's a passive probe designed for high-fidelity measurements.
  • High Bandwidth Offers a bandwidth of >700 MHz.
  • Low Capacitive Loading  Features a low input capacitance of <4 pF.
  • Attenuation Ratio Has an attenuation ratio of 25:1.
  • Universal Output Includes a universal BNC output connector for compatibility with various oscilloscopes.

Wide-Band AC Current Transformers 13E1000

  • Wide-band current transformer with over 60 MHz bandwidth and 1000 A current rating
  • Delivers 1 mV/A output sensitivity with < 2% accuracy and rise time under 6 ns
  • Low insertion inductance of 300 nH and excellent DC saturation tolerance up to 2000 A
  • Features integrated 50 Ω termination and BNC (male) output connector for easy connection
  • Compact and robust design with 21 mm aperture, 1.5 m cable, and galvanic isolation
Placeholder for ajax description replacement