High Voltage Differential Probes BumbleBee® Series
הצג
Placeholder for ajax description replacement

Camera Adapter 1/4" to M6 (SW 13mm)

  • The Camera Adapter is designed to mount cameras with a 1/4" thread.
  • It has an M6 thread for mounting on the SKID® positioning systems.
  • The adapter features a hex socket (SW 13mm).
  • Used to securely attach cameras and other equipment with a 1/4" thread to the SKID® systems.
  • Facilitates the use of cameras and other compatible equipment with the SKID® positioning systems.

Clamb Lever V2A

  • Clamb Lever V2A made from corrosion and acid-resistant V2A stainless steel
  • Designed for single-handed operation
  • Used as a component within the PMK SKID® positioning system
  • Operates reliably across a wide temperature range from -55°C to +155°C
  • Durable and reliable for clamping applications in various testing and measuring environments

Coil Current Probes SS-280A / A-H

  • Model SS-280A / A-H features a Rogowski coil design for AC current measurement
  • Hard-shell A-H version offers enhanced mechanical protection
  • Provides a linear voltage output signal proportional to the measured current
  • Supports wide bandwidth and high-frequency current waveforms
  • Designed for use in tight installation spaces and electrical panels

EMC Noise Suppression Kit

  • Accessory for BumbleBee® high-voltage differential probes
  • Designed for use in EMI-heavy environments
  • Helps suppress noise and improve measurement accuracy
  • Includes three ferrites for effective interference reduction
  • Supplied with an opening key for easy installation

High Impedance Active Probe Sonic® 4000 RF

  • High-Frequency Probe The Sonic 4000 RF active probe is designed for high-frequency in-circuit measurements, with a bandwidth of 220 Hz to >4 GHz.
  • Input Impedance It features a high input impedance of 2MΩ in parallel with <0.6pF, minimizing circuit loading.
  • Output The probe's output signal has no DC component.
  • Safe Probing It has a high impedance probe tip reference connection (1MΩ to earth ground) for safe in-circuit browsing and to prevent short circuits.
  • Applications It is ideal for use with spectrum, network, and RF analyzers, as well as other 50Ω measurement systems.

High Impedance Active Probe Tetris® 1000

  • 1 GHz Bandwidth for accurate high-frequency signal measurements

  • ±8 V Dynamic Range supports a wide range of signal levels

  • High Input Impedance of >1 MΩ with low 0.9 pF capacitance for minimal circuit loading

  • 10:1 Attenuation Ratio ensures safe signal scaling for sensitive instruments

  • Compact and Lightweight with 1.3 m cable and BNC output for universal oscilloscope compatibility

High Speed Pulse Generator USB FastEdge® 

  • The Fedge® is a compact, USB-powered fast edge signal generator, about the size of a USB stick.

  • It delivers a very square and flat -500 mV pulse with a rapid 32 ps edge.

  • This pulse has no overshoot or undershoot, making it ideal for verifying instrument and probe rise/fall times.

  • Features single-button operation for selecting different operating modes.

  • Can be used for bandwidth measurements, TDR measurements, and even EMV tests.

High Voltage Differential Probe BumbleBee®±2000V, 2m

  • High Voltage Differential Probe – Designed for measuring high voltage differentials, up to ±2000V.
  • 2m Cable Length – Comes with a 2-meter cable for flexible measurement setups.
  • Adjustable Attenuation – Offers four selectable input attenuation ranges (500:1, 250:1, 100:1, 50:1) to optimize the signal for the best resolution.
  • Wide Bandwidth – Supports bandwidth up to 400 MHz (depending on attenuation setting).
  • Universal BNC Output – Features a universal BNC output connector for compatibility with various oscilloscopes.

high voltage differential probe HORNET® ±4000V

  • ±4000V differential and common mode input range for high-voltage applications
  • Bandwidth exceeding 300MHz with rise times down to 1.0 ns
  • Multiple attenuation ranges: 1000:1, 500:1, 200:1, 100:1
  • Designed for integration into automated or manual test stations (not handheld)
  • Compatible with oscilloscopes via universal BNC output, requires separate PMK power supply

High voltage optically isolated probe FireFly® SMA Input

  • High Bandwidth – Offers a bandwidth greater than 1.5 GHz.
  • Low Input Range – Designed for a low input voltage range of ±1V.
  • High Input Impedance – Has an input impedance of 200 kΩ || 5.1 pF.
  • Fast Rise Time – Features a rise time of less than 250 ps.
  • High CMRR – Exhibits a high Common Mode Rejection Ratio (CMRR).

High Voltage Passive Probe PHV 1000

  • It is a high voltage passive probe. This means it's designed to measure high voltages without needing its own power source, relying on the signal from the circuit it's testing.
  • It has an attenuation ratio of 100:1. This indicates that the probe reduces the input voltage to 1/100th of its actual value, allowing standard oscilloscopes to measure high voltages safely. The attenuation ratio has an accuracy of ±2% at DC.
  • It has a system bandwidth of 120 MHz. This specifies the frequency range over which the probe can accurately measure voltage signals. It also has a rise time of 2.4 ns.
  • The input resistance is 50 MΩ. This high input resistance minimizes the loading effect on the circuit being measured, ensuring accurate readings. The input capacitance is 9.5 pF.
  • It is designed for use with a measuring instrument having an input coupling of 1 MΩ AC/DC. This defines the input impedance that the measuring instrument (typically an oscilloscope) should have for the probe to function correctly.

High Voltage Passive Probes HV-P30A

  • It is a high voltage passive probe designed for high voltage measurements.
  • It has an attenuation ratio of 1000:1.
  • The maximum DC input voltage is 30 kV, and the maximum frequency band voltage is 40 kV.
  • It has a system bandwidth of 50 MHz.
  • It is intended for use in a protected test environment and is not designed for handheld use.
Showing 36 of 99 items
Load More
Placeholder for ajax description replacement