High Voltage Differential Probes BumbleBee® Series
הצג
Placeholder for ajax description replacement

High Voltage Passive Probes PHV 1000-O

  • It is a high-voltage probe designed for use with the OMICRON Lab Bode 100 vector network analyzer.
  • It has a maximum input voltage of 2000V peak.
  • It features a 100:1 attenuation ratio.
  • The system has an input resistance of 50 MΩ and an input capacitance of 7.5 pF.
  • It comes with accessories for easy adaptation to the device under test (DUT).

High Voltage Passive Probes PHVX4kV-2-0

  • It's a passive high voltage probe designed for measurements in power electronics design.
  • It has a maximum input voltage rating of 4000V DC / 4000V peak.
  • It features a bandwidth greater than 600MHz and a 100:1 attenuation ratio.
  • It comes with a 2.0m cable length.
  • It does not include readout function or additional Silicon insulation.

High Voltage Probe Calibration Generators KHT 6000C

  • The KHT 6000C is a calibration generator specifically designed for HF adjustment of high voltage probes and dividers.
  • It generates square pulses with a voltage range of 500V to 6000V, adjustable in 1V steps.
  • The device features a steep rising edge with a rise time of less than 45ns (10% to 90%).
  • Users can operate the KHT 6000C manually or remotely via a PC using the integrated USB or optional GPIB interface.
  • Key specifications include a voltage display resolution of 1V and a maximum load of 100pF.

High-Speed Differential Probe HSDP4010

  • High Bandwidth Offers a bandwidth greater than 4 GHz, with 4.2 GHz typical.
  • Differential Voltage Range Designed for a differential voltage range of ±8V (16Vpp).
  • Low Noise Features low input-referred noise, less than 2 mV rms and 100 nV/sqrt(Hz) (preliminary).
  • Fast Rise Time Has a rise time of less than 140 ps (preliminary).
  • High CMRR Exhibits high Common Mode Rejection Ratio (CMRR) with >70 dB at DC, >50 dB at 1 MHz, >45 dB at 10 MHz, >35 dB at 100 MHz, >25 dB at 500 MHz and >25 dB at 1 GHz.

Holder for Probes 5-12mm

  • Versatile holder for probes sized 5mm to 12mm
  • Designed for SKID® positioning systems
  • Included in some SKID Starter Kits (SKID-M, SKID-L)
  • Enables precise probe positioning for testing and debugging
  • Durable accessory to enhance SKID® system functionality

Interface power supply push/pull 1.5m

  • 1.5 m interface cable for PMK active probes
  • Reliable connection to compatible power supplies
  • Push/Pull connector design for quick and secure attachment
  • Durable high-quality construction for long-term use
  • Provides flexibility and stable power delivery in test setups

Non-sellable single item of spring tip set

  • Single spring tip from the PMK set, not sold individually
  • Gold-plated for enhanced durability and reliable conductivity
  • Fine tip suitable for precision and delicate tasks
  • Intended as a replacement or spare for the full set
  • Compatible with PMK soldering and testing tools

Optional probe single case in black with foam inlay for transport and storage Case BumbleBee

  • Optional single probe case for BumbleBee series
  • Durable black exterior for long-lasting use
  • Foam inlay provides secure protection
  • Compact and lightweight for easy transport
  • Ideal for safe storage and professional mobility

Passive High-Temperature Probe ENVI® 4.5MΩ

  • It's a passive probe designed for environmental testing and use in climatic chambers within a wide temperature range of -55°C to +155°C.
  • It features a 10:1 attenuation ratio, a 350 MHz bandwidth, and a 400V input voltage range.
  • The probe has a BNC connector with a read-out function for universal connectivity to oscilloscopes with BNC input, enabling direct voltage measurement display.
  • It is suitable for a variety of applications due to its high temperature range and voltage input capabilities.
  • It has an input resistance of 4.5 MΩ and an input capacitance of 20 pF.

Passive Probe MMCX-P0725

  • Passive Probe – It's a passive probe designed for high-fidelity measurements.
  • High Bandwidth Offers a bandwidth of >700 MHz.
  • Low Capacitive Loading  Features a low input capacitance of <4 pF.
  • Attenuation Ratio Has an attenuation ratio of 25:1.
  • Universal Output Includes a universal BNC output connector for compatibility with various oscilloscopes.

Passive Probes PML 701

  • It is a 1:1 passive probe.
  • It has a system bandwidth of 38 MHz and a rise time of 9 ns.
  • The system's input resistance is 1 MΩ (Scope Input), and the input capacitance is 39 pF + Scope.
  • It is designed for use with a measuring instrument with 1MΩ AC/DC input coupling.
  • The probe is light, weighing only 43g, and has a cable length of 1.3m and a probe tip diameter of 2.5mm

PCB Adapter 2.5

  • Basic adapter for use with spring-loaded probe tips
  • Made from nickel-plated spring steel for durability
  • Rated for 250 V input voltage
  • Handles up to 1600 V pulse
  • Requires minimum solder pad spacing of 1.25 mm