High Voltage Differential Probes BumbleBee® Series
הצג
Placeholder for ajax description replacement

Oscilloscope Probe PP215

  • Bandwidth up to 200 MHz in 10X mode for high-frequency signal analysis
  • Switchable 1X/10X attenuation for versatile measurement applications
  • Compatible with oscilloscopes with 1 MΩ input impedance
  • Wide compensation range from 10 pF to 35 pF ensures calibration flexibility
  • Rugged 130 cm cable and robust design for lab and field use

Oscilloscope Probe PP430

  • High-performance passive oscilloscope probe with 1X/10X attenuation switch
  • 300 MHz bandwidth in 10X mode for accurate high-speed signal capture
  • Compatible with 1 MΩ input impedance oscilloscopes
  • Wide compensation range of 10–35 pF for optimal calibration
  • Durable 130 cm cable and robust design ideal for lab and field use

Oscilloscope Probe PP510

  • Switchable 1X / 10X attenuation for versatile signal probing
  • Higher bandwidth than entry-level models — suitable for mid-speed signals
  • Compatible with oscilloscopes featuring 1 MΩ input impedance
  • Adjustable compensation range for matching probe to oscilloscope
  • Robust construction with standard 130 cm cable length
  • CAT II rated input voltage for safe use on typical lab signals

Oscilloscope Probes P6500

  • 500 MHz bandwidth passive oscilloscope probe with 10X attenuation
  • High input impedance of 10 MΩ and low input capacitance of 11 pF
  • Supports up to 600 V input (DC + AC peak-to-peak) at 10X setting
  • Compensation range from 9 pF to 25 pF for calibration flexibility
  • Durable 122 cm cable with black injection-molded integrated housing

Oscilloscope Probes SP2030A

  • High-performance 10X passive oscilloscope probe with 300 MHz bandwidth
  • Supports Auto-Sense function for seamless oscilloscope integration
  • 10 MΩ input impedance and 12 pF capacitance for accurate signal capture
  • Rated for up to 300 V RMS; ideal for lab, R&D, and debugging use
  • Includes 130 cm cable and lightweight 55 g design for comfortable handling

Oscilloscope Probes SP2035A

  • 350 MHz bandwidth 10X passive oscilloscope probe for high-frequency applications
  • Auto-Sense feature ensures automatic recognition by compatible oscilloscopes
  • 10 MΩ input impedance and 12 pF capacitance for minimal circuit loading
  • Rated for up to 300 V RMS with robust and durable construction
  • Includes a 130 cm cable for flexible and convenient measurements

Oscilloscope Probes SP3050A

  • 500 MHz bandwidth for accurate high-speed signal measurements
  • 10X attenuation with 10 MΩ input impedance and 11 pF capacitance
  • Rated for up to 400 V CAT II for safe voltage probing
  • Compact and lightweight design, ideal for precision R&D work
  • Compatible with oscilloscopes via standard BNC and 120 cm cable length

Pair of Probe Tip Adaptors 4mm to 0.8mm (2x black)

  • Converts standard 4 mm probe connection to fine 0.8 mm tip
  • Provides secure and precise contact with small test points
  • Ideal for probing PCBs and compact electronic components
  • Supplied as a pair (2x black) for added convenience
  • Enhances measurement flexibility in tight spaces

Passive High-Temperature Probe ENVI® 4.5MΩ

  • It's a passive probe designed for environmental testing and use in climatic chambers within a wide temperature range of -55°C to +155°C.
  • It features a 10:1 attenuation ratio, a 350 MHz bandwidth, and a 400V input voltage range.
  • The probe has a BNC connector with a read-out function for universal connectivity to oscilloscopes with BNC input, enabling direct voltage measurement display.
  • It is suitable for a variety of applications due to its high temperature range and voltage input capabilities.
  • It has an input resistance of 4.5 MΩ and an input capacitance of 20 pF.

Passive Probe MMCX-P0725

  • Passive Probe – It's a passive probe designed for high-fidelity measurements.
  • High Bandwidth Offers a bandwidth of >700 MHz.
  • Low Capacitive Loading  Features a low input capacitance of <4 pF.
  • Attenuation Ratio Has an attenuation ratio of 25:1.
  • Universal Output Includes a universal BNC output connector for compatibility with various oscilloscopes.

Passive Probes PML 701

  • It is a 1:1 passive probe.
  • It has a system bandwidth of 38 MHz and a rise time of 9 ns.
  • The system's input resistance is 1 MΩ (Scope Input), and the input capacitance is 39 pF + Scope.
  • It is designed for use with a measuring instrument with 1MΩ AC/DC input coupling.
  • The probe is light, weighing only 43g, and has a cable length of 1.3m and a probe tip diameter of 2.5mm

PCB Adapter 2.5

  • Basic adapter for use with spring-loaded probe tips
  • Made from nickel-plated spring steel for durability
  • Rated for 250 V input voltage
  • Handles up to 1600 V pulse
  • Requires minimum solder pad spacing of 1.25 mm