High Voltage Differential Probes BumbleBee® Series
הצג
Placeholder for ajax description replacement

High Voltage Passive Probes PHVX4kV-2-0

  • It's a passive high voltage probe designed for measurements in power electronics design.
  • It has a maximum input voltage rating of 4000V DC / 4000V peak.
  • It features a bandwidth greater than 600MHz and a 100:1 attenuation ratio.
  • It comes with a 2.0m cable length.
  • It does not include readout function or additional Silicon insulation.

Passive High-Temperature Probe ENVI® 4.5MΩ

  • It's a passive probe designed for environmental testing and use in climatic chambers within a wide temperature range of -55°C to +155°C.
  • It features a 10:1 attenuation ratio, a 350 MHz bandwidth, and a 400V input voltage range.
  • The probe has a BNC connector with a read-out function for universal connectivity to oscilloscopes with BNC input, enabling direct voltage measurement display.
  • It is suitable for a variety of applications due to its high temperature range and voltage input capabilities.
  • It has an input resistance of 4.5 MΩ and an input capacitance of 20 pF.

High Impedance Active Probe Tetris® 1000

  • 1 GHz Bandwidth for accurate high-frequency signal measurements

  • ±8 V Dynamic Range supports a wide range of signal levels

  • High Input Impedance of >1 MΩ with low 0.9 pF capacitance for minimal circuit loading

  • 10:1 Attenuation Ratio ensures safe signal scaling for sensitive instruments

  • Compact and Lightweight with 1.3 m cable and BNC output for universal oscilloscope compatibility

High Impedance Active Probe Sonic® 4000 RF

  • High-Frequency Probe The Sonic 4000 RF active probe is designed for high-frequency in-circuit measurements, with a bandwidth of 220 Hz to >4 GHz.
  • Input Impedance It features a high input impedance of 2MΩ in parallel with <0.6pF, minimizing circuit loading.
  • Output The probe's output signal has no DC component.
  • Safe Probing It has a high impedance probe tip reference connection (1MΩ to earth ground) for safe in-circuit browsing and to prevent short circuits.
  • Applications It is ideal for use with spectrum, network, and RF analyzers, as well as other 50Ω measurement systems.

Active Probe Sonic® 4000

  • The Sonic 4000 active probe offers best-in-class performance for in-circuit measurements.
  • It has a bandwidth from DC to >4 GHz, high input impedance, low noise, and a ±8V dynamic range.
  • The probe's ±12V input offset capability extends its input voltage range.
  • It features an input capacitance of <0.6 pF and 2MΩ input resistance to minimize circuit loading.
  • The probe tip reference connection has a high impedance to earth ground for safe in-circuit probing.

Active Probe ATE2000 with ground blade

  • For Automated Test Equipment (ATE) Designed for in-circuit measurements within automated test environments.
  • High Bandwidth Offers a bandwidth of >2.5 GHz.
  • Voltage Range Has an input dynamic voltage range of ±8V (16Vpp) and an input offset voltage range of ±12V.
  • High Input Impedance Features a high input resistance of 1 MΩ (input to ground) to prevent shorting the test point.
  • Ground Blade Includes a ground blade for repeatable measurements.

High-Speed Differential Probe HSDP4010

  • High Bandwidth Offers a bandwidth greater than 4 GHz, with 4.2 GHz typical.
  • Differential Voltage Range Designed for a differential voltage range of ±8V (16Vpp).
  • Low Noise Features low input-referred noise, less than 2 mV rms and 100 nV/sqrt(Hz) (preliminary).
  • Fast Rise Time Has a rise time of less than 140 ps (preliminary).
  • High CMRR Exhibits high Common Mode Rejection Ratio (CMRR) with >70 dB at DC, >50 dB at 1 MHz, >45 dB at 10 MHz, >35 dB at 100 MHz, >25 dB at 500 MHz and >25 dB at 1 GHz.

Passive Probe MMCX-P0725

  • Passive Probe – It's a passive probe designed for high-fidelity measurements.
  • High Bandwidth Offers a bandwidth of >700 MHz.
  • Low Capacitive Loading  Features a low input capacitance of <4 pF.
  • Attenuation Ratio Has an attenuation ratio of 25:1.
  • Universal Output Includes a universal BNC output connector for compatibility with various oscilloscopes.

High voltage optically isolated probe FireFly® SMA Input

  • High Bandwidth – Offers a bandwidth greater than 1.5 GHz.
  • Low Input Range – Designed for a low input voltage range of ±1V.
  • High Input Impedance – Has an input impedance of 200 kΩ || 5.1 pF.
  • Fast Rise Time – Features a rise time of less than 250 ps.
  • High CMRR – Exhibits a high Common Mode Rejection Ratio (CMRR).

High Voltage Differential Probe BumbleBee®±2000V, 2m

  • High Voltage Differential Probe – Designed for measuring high voltage differentials, up to ±2000V.
  • 2m Cable Length – Comes with a 2-meter cable for flexible measurement setups.
  • Adjustable Attenuation – Offers four selectable input attenuation ranges (500:1, 250:1, 100:1, 50:1) to optimize the signal for the best resolution.
  • Wide Bandwidth – Supports bandwidth up to 400 MHz (depending on attenuation setting).
  • Universal BNC Output – Features a universal BNC output connector for compatibility with various oscilloscopes.
Placeholder for ajax description replacement