מומחי הפרובים מחכים

972-03-923-2277+

אין כלום בעגלה שלך.

מצאו את הפרוב המתאים לכם

פרובים מכל הסוגים
מתאימים לכל החברות

עכשיו

במחירי השקה

High Voltage Differential Probes BumbleBee® Series
הצג
Placeholder for ajax description replacement

Allen Wrench 2.5mm

  • The Allen Wrench 2.5mm is a tool designed for use with SKID® positioning systems.
  • Specifically for tightening and loosening components that require a 2.5mm Allen wrench.
  • A component of the SKID® positioning systems.
  • Tool design for precise fastening tasks.
  • Wrench size: 2.5mm.

ASP-18 Adjustable Single-end TDR probe DC~18 GHz

  • DC to 18 GHz frequency range for high-speed TDR and impedance testing
  • Adjustable probe spacing from 0 to 6.5 mm with precision wheel
  • 50 Ω impedance with low insertion loss and excellent repeatability
  • SMA connector interface; optional customizable cable end (SMA/N-type)
  • Ideal for PCBs, cables, and fine-pitch high-frequency measurements

ASP-26 Adjustable Single-end TDR probe DC~26.5 GHz

  • DC to 26.5 GHz bandwidth for high-speed TDR and impedance testing
  • Adjustable probe spacing from 0 to 6.5 mm with precision control
  • 50 Ω impedance with low signal loss and high measurement repeatability
  • SMA connector interface; customizable cable end (SMA or N-type)
  • Ideal for PCBs, cables, and high-frequency component testing

Board Tester SKID-L Starter Kit (340×300 mm)

  • Hands-free testing and debugging platform for PCBA
  • Supports boards larger than 6U, up to 300×340 mm clamping width
  • Modular design with M6 threads for mounting accessories
  • Compatible with non-standard board shapes and heavy devices
  • Operating temperature: 0 °C to +50 °C, non-condensing humidity

Camera Adapter 1/4" to M6 (SW 13mm)

  • The Camera Adapter is designed to mount cameras with a 1/4" thread.
  • It has an M6 thread for mounting on the SKID® positioning systems.
  • The adapter features a hex socket (SW 13mm).
  • Used to securely attach cameras and other equipment with a 1/4" thread to the SKID® systems.
  • Facilitates the use of cameras and other compatible equipment with the SKID® positioning systems.

Clamb Lever V2A

  • Clamb Lever V2A made from corrosion and acid-resistant V2A stainless steel
  • Designed for single-handed operation
  • Used as a component within the PMK SKID® positioning system
  • Operates reliably across a wide temperature range from -55°C to +155°C
  • Durable and reliable for clamping applications in various testing and measuring environments

Coil Current Probes SS-280A / A-H

  • Model SS-280A / A-H features a Rogowski coil design for AC current measurement
  • Hard-shell A-H version offers enhanced mechanical protection
  • Provides a linear voltage output signal proportional to the measured current
  • Supports wide bandwidth and high-frequency current waveforms
  • Designed for use in tight installation spaces and electrical panels

Current Probe CP4020

  • 100 kHz bandwidth for accurate AC/DC current measurements
  • Supports 20 Arms continuous and up to 60 A peak current
  • Dual sensitivity: 50 mV/A and 2 mV/A for flexible diagnostics
  • ±2% typical accuracy for precise results in test environments
  • Compact, battery-powered design ideal for field and lab use

Current Probe CP4050

  • Bandwidth: DC to 1 MHz
  • Peak current measurement up to 140 A
  • Dual sensitivity: 500 mV/A and 50 mV/A
  • DC measurement accuracy: ±3% ±20 mA (500 mV/A); ±4% ±200 mA (50 mV/A)
  • Maximum conductor diameter: 10.3 mm

Current Probe CP4070

  • Measures up to 200A AC/DC.
  • Bandwidth of 150 kHz.
  • Easy BNC connection to oscilloscopes.
  • Suitable for use with a wide range of instruments, including Siglent oscilloscopes.
  • Ideal for power electronics, automotive, and industrial applications.

Current Probe CP4070A

  • DC to 300 kHz bandwidth
  • 70 A RMS / 200 A peak current range
  • Dual range: 100 mV/A and 10 mV/A
  • Accuracy: ±2% typical
  • Fast rise time: ≤1.2 µs

Current Probe CP5030

  • 50 MHz bandwidth with ≤7 ns rise time
  • Current ranges: 5 A (1X), 30 A (10X)
  • Transfer ratios: 1 V/A (5 A), 0.1 V/A (30 A)
  • Accuracy: ±1% ±1 mA (5 A), ±1% ±10 mA (30 A)
  • Resolution: 1 mA / 10 mA
Showing 36 of 142 items
Load More
Placeholder for ajax description replacement